10.Measure from the base of the escutcheon to the
surface of the finished wall and note the dimension of
this gap.
11.Remove the handle assembly, trim connector and trim
sleeve (5). Cut the cartridge stem (4), and trim sleeve
by an amount equal to the dimension obtained in step
9.
12.Thread the trim sleeve and handle trim connector
back onto the valve. If the escutcheon (15) does not
contact the wall, cut an additional amount off of the
cartridge stem and/or the trim sleeve.
13.If desired, a bead of caulk or silicone may be applied
where the escutcheon contacts the wall.
14.Hand tightening the handle assembly is adequate; if
this assembly is too tight, the handle will bind.
SPOUT INSTALLATION:
15.Unpack the spout and verify the spout adapter (1)
is threaded completely into the spout.
16.To verify alignment of the spout and adapter, make a
mark at 12:00 that extends from the spout onto the
adapter.
17.Unthread the adapter from the spout then slide the
adapter onto the copper. The face of the adapter
should NOT extend more than 1
1
4
" off the face of
the finished wall.
18.After verifying fit, make sure the mark made in step 16
remains at 12:00 then sweat the adapter onto the
copper. If it is not aligned, the spout will not thread on
completely and cause a leak or not align properly so
the tip points down at 6:00.
19.Allow the adapter to cool then slide the escutcheon
onto the adapter.
20.Thread the spout onto the adapter making sure the
washer (22) is in place.
DRAIN INSTALLATION
Note: This faucet does not use a lift rod to
operate the drain stopper. Instead, it uses a
simple pop-up drain that is closed and opened
by pushing down on the stopper.
21.Remove the upper collar from the pop-up drain
assembly and discard the upper gasket.
22.Set the upper collar in the lavatory drain opening
using a clear adhesive silicone.
23.Re-attach the lower drain assembly using the gasket
provided then tighten until fully secured. A clear
adhesive silicone may be used to ensure a water-tight
seal between the gasket and lavatory.
24.Attach the tail piece using the gasket provided.
INSPECT THE INSTALLATION
25.Remove the flow restrictor assembly (13) from the
spout using the tool provided. Carefully open the hot
and cold valves to flush out any debris in the supply
lines.
26.Inspect all connections for leaks. Reinstall the flow
restrictor assembly.
27.Push down on the drain stopper to close the drain
then fill the sink with water to make sure the stopper
operates and seals properly.
28.Push down on the stopper to open the drain. If the
stopper has to be removed, simply pull up on the
stopper which will also remove the strainer.
If further assistance is required, please contact Product
Support at 1-800-927-2120 (8am-7pm EST)
These guidelines have been prepared for the professional contractor to aid in the installation of:
.25 WALL MOUNTED LAVATORY FAUCET WITH CROSS HANDLES (PTLS05-K &
GUSV27R) & LEVER HANDLES (PTLS06-K & GUSV25R) All dimensions are based on origin
specification and are subject to change and variation. Please consult your Design Associate for current
specifications.
04.11.07