Installation guidelines – Waterworks Henry Thermostatic with Shutoff Trim User Manual
Page 3

PRODUCT SUPPORT 800.927.2120 8am - 6pm EST
HENRY
Thermostatic with Shutoff Trims
INSTALLATION GUIDELINES
Page 3 of 3
11.14.2012
These guidelines have been prepared for the professional contractor to aid in the installation of:
HENRY METAL LEVER HANDLE WITH THERMOSTATIC WITH METAL CROSS HANDLE SHUTOFF
TRIMS (STYLE# HNTH30)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
SEE SERVICE PART DOCUMENT FOR PART ORDERING, AVAILABLE ON WATERWORKS.COM
14. Slowly rotate the square tube clockwise to attain full
cold, then rotate it counterclockwise to attain full
hot. Verify a full range of temperature exists. Note: It
is approximately 2 complete rotations from full cold
to full hot.
15. With water running, rotate the square tube to adjust
the temperature to the maximum desired bathing
temperature, verified with a thermometer. Turn the
water off and make sure not to change this
temperature.
16. Unthread the lever handle assembly from the limit
stop housing and loosen the set screws on the
housing.
17. Insert the limit stop assembly onto the trim nut,
making sure the limit stop pin makes contact with
the limit stop on the trim plate, then tighten the set
screws.
Figure - 04
Limit Stop
Pin
Limit Stop
Limit Stop
Housing
Set Screw
Lever Handle
Assembly
INSPECT THE INSTALLATION:
18. Turn the limit stop assembly clockwise, turn the
water on and confirm the limit stop functions
properly by turning it counterclockwise at which
point it should stop.
19. Verify the temperature to be the maximum
temperature set in Step 15. If it is not the correct
temperature, repeat the calibration procedures.
20. To get a hotter temperature, press and hold the limit
stop button then rotate the limit stop until it stops. It
is NOT recommended to exceed the safety limit
stop of 110 degrees.
21. Re-attach the lever handle assembly to the limit stop
assembly.
¾
If further assistance is required, please contact
Product Support at 1-800-927-2120 (8am-6pm EST).
¾
See service part document for parts ordering,
available on WATERWORKS.COM.