Order information, X n h, B-series temperature switch model number – Pilgrim Pressure Switches B-SERIES User Manual

Page 7

Advertising
background image

7

ORDER INFORMATION

B-SERIES TEMPERATURE SWITCH MODEL NUMBER:

To specify the exact switch desired, select entries from appropriate tables
as shown in example below.

T 4

2

0

T 0

5 030

1

4

2

3

X N H

5

150° to 260°F

6

1 – ENCLOSURE

Temperature switch, Type 400, watertight enclosure

T4

meets NEMA 3, 4, 4X, 13 and IP66 requirements.

Temperature switch, Type 700, explosion-proof

T7

enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66
requirements.

3 – THERMAL SYSTEM SELECTION

Direct Mount

Order Code

System Material

Style

TS

3l6 SS

Rigid

Remote Mount

Order Code System Material Line Length

Style

(9)

T05

316 SS

5´

Capillary

T10

316 SS

10´

with

T15

316 SS

15´

302 SS

T20

316 SS

20´

Spring

T25

316 SS

25´

Armor

4 – BULB LENGTH SELECTION

Direct Mount

Minimum

Order

“S”

Thermowell

Code

Dimension

“U” Dimension

027

(8)

2

3

⁄

4

˝

–

040

4˝

2

1

⁄

2

˝

060

6˝

4

1

⁄

2

˝

090

9˝

7

1

⁄

2

˝

120

12˝

10

1

⁄

2

˝

Remote Mount

030

(9)

3˝

2

1

⁄

2

˝

5 – OPTIONS

Use table on

page 10

6 – STANDARD TEMPERATURE

RANGE SELECTION

Adjustable Range

°F

°C

–40 to 60

0

–40 to 16

0

0 to 100

–40 to 40

0

75 to 205

20 to 95

150 to 260

65 to 125

235 to 375

110 to 190

350 to 525

175 to 275

500 to 750

(2)

260 to 400

2 – SWITCH ELEMENT SELECTION

Order

Switch Elements

Code

UL/CSA Listed SPDT

20

(7)

Narrow deadband ac

15A, 125/250 Vac

21

Ammonia service

5A, 125/250 Vac

22

(6)

Hermetically sealed switch,

5A, 125/250 Vac

narrow deadband

23

Heavy duty ac

22A, 125/250 Vac

24

(1)

General purpose

15A, 125/250/480 Vac

1

⁄

2

A, 125 Vdc

1

⁄

4

A, 250 Vdc; 6A, 30 Vdc

25

Heavy duty dc

10A, 125 Vac or dc,

1

⁄

8

HP, 125 Vac or dc

26

(7)

Sealed environment proof

15A, 125/250 Vac

27

High temperature 300°F

15A, 125/250 Vac

28

(5)

Manual reset trip on

15A, 125/250 Vac

increasing

29

(5)

Manual reset trip on

15A, 125/250 Vac

decreasing

31

Low level (gold) contacts

1A, 125 Vac

32

Hermetically sealed switch,

11A, 125/250 Vac

general purpose

5A, 30 Vdc

50

Variable deadband

15A, 125/250 Vac

UL/CSA Listed Dual (2 SPDT)

61

(7)

Dual narrow deadband

15A, 125/250 Vac

62

(7)

Dual sealed environment

15A, 125/250 Vac

proof

63

Dual high temp. 300°F

15A, 125/250 Vac

64

Dual general purpose

15A, 125/250/480 Vac

1

⁄

2

A, 125 Vdc

1

⁄

4

A, 250 Vdc

65

Dual ammonia service

5A, 125/250 Vac

67

(4,6)

Dual hermetically sealed

5A, 125/250 Vac

switch, narrow deadband

68

(4)

Dual hermetically sealed

11A, 125/250 Vac

switch, general purpose

5A, 30 Vdc

71

(4)

Dual hermetically sealed

1A, 125 Vac

switch, gold contacts

NOTES:

1 Standard switch.
2 Available with remote mount

thermal systems only.

3 Dual switches are 2 SPDT

snap-action switches, not
independently adjustable.

4 Wires cannot be terminated

inside T400 switch enclosure.

5 Not available with Type 700

T4 direct mount

model shown

enclosure.

6 Estimated dc rating, 2.5A,

28 Vdc (not UL listed).

7 Estimated dc rating, 0.4A,

120 Vdc (not UL listed).

8 Not available on 350 to 525°F.
9 Consult factory on remote

mount for bulb lengths other
than 3.˝

Advertising