Exposure controls/personal protection – Chemtronics Electro-Wash MX ES1621 User Manual
Page 5

Electro-Wash® MX
8. Exposure controls/personal protection
STEL: 500 ppm 15 minutes.
TWA: 980 mg/m³ 8 hours.
TWA: 400 ppm 8 hours.
propyl acetate
ACGIH TLV (United States, 6/2013).
STEL: 1040 mg/m³ 15 minutes.
STEL: 250 ppm 15 minutes.
TWA: 835 mg/m³ 8 hours.
TWA: 200 ppm 8 hours.
NIOSH REL (United States, 4/2013).
STEL: 1050 mg/m³ 15 minutes.
STEL: 250 ppm 15 minutes.
TWA: 840 mg/m³ 10 hours.
TWA: 200 ppm 10 hours.
OSHA PEL (United States, 2/2013).
TWA: 840 mg/m³ 8 hours.
TWA: 200 ppm 8 hours.
OSHA PEL 1989 (United States, 3/1989).
STEL: 1050 mg/m³ 15 minutes.
STEL: 250 ppm 15 minutes.
TWA: 840 mg/m³ 8 hours.
TWA: 200 ppm 8 hours.
Carbon dioxide
ACGIH TLV (United States, 6/2013). Oxygen Depletion
[Asphyxiant].
STEL: 54000 mg/m³ 15 minutes.
STEL: 30000 ppm 15 minutes.
TWA: 9000 mg/m³ 8 hours.
TWA: 5000 ppm 8 hours.
NIOSH REL (United States, 4/2013).
STEL: 54000 mg/m³ 15 minutes.
STEL: 30000 ppm 15 minutes.
TWA: 9000 mg/m³ 10 hours.
TWA: 5000 ppm 10 hours.
OSHA PEL (United States, 2/2013).
TWA: 9000 mg/m³ 8 hours.
TWA: 5000 ppm 8 hours.
OSHA PEL 1989 (United States, 3/1989).
STEL: 54000 mg/m³ 15 minutes.
STEL: 30000 ppm 15 minutes.
TWA: 18000 mg/m³ 8 hours.
TWA: 10000 ppm 8 hours.
Engineering measures
:
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or
other engineering controls to keep worker exposure to airborne contaminants below any
recommended or statutory limits. The engineering controls also need to keep gas,
vapor or dust concentrations below any lower explosive limits. Use explosion-proof
ventilation equipment.
Hygiene measures
:
Wash hands, forearms and face thoroughly after handling chemical products, before
eating, smoking and using the lavatory and at the end of the working period.
Appropriate techniques should be used to remove potentially contaminated clothing.
Wash contaminated clothing before reusing. Ensure that eyewash stations and safety
showers are close to the workstation location.
Recommended monitoring
procedures
:
If this product contains ingredients with exposure limits, personal, workplace
atmosphere or biological monitoring may be required to determine the effectiveness of
the ventilation or other control measures and/or the necessity to use respiratory
protective equipment. Reference should be made to appropriate monitoring standards.
Reference to national guidance documents for methods for the determination of
hazardous substances will also be required.
5/11
0219
5/2/2014.