6. Accidental release measures
Stop leak if without risk. Move containers from spill area. Approach release from
upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash
spillages into an effluent treatment plant or proceed as follows. Contain and collect
spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or
diatomaceous earth and place in container for disposal according to local regulations
(see Section 13). Dispose of via a licensed waste disposal contractor. Contaminated
absorbent material may pose the same hazard as the spilled product. Note: see
Section 1 for emergency contact information and Section 13 for waste disposal.
Large spill
:
Stop leak if without risk. Move containers from spill area. Dilute with water and mop up
if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and
place in an appropriate waste disposal container. Dispose of via a licensed waste
disposal contractor.
Small spill
:
Store in accordance with local regulations. Store away from direct sunlight in a dry, cool
and well-ventilated area, away from incompatible materials (see Section 10) and food
and drink. Use appropriate containment to avoid environmental contamination.
Put on appropriate personal protective equipment (see Section 8). Eating, drinking and
smoking should be prohibited in areas where this material is handled, stored and
processed. Workers should wash hands and face before eating, drinking and smoking.
Remove contaminated clothing and protective equipment before entering eating areas.
Pressurized container: protect from sunlight and do not expose to temperatures
exceeding 50°C. Do not pierce or burn, even after use. Avoid exposure - obtain special
instructions before use. Do not get in eyes or on skin or clothing. Do not ingest. Avoid
breathing gas. Avoid breathing vapor or mist. Use only with adequate ventilation.
Wear appropriate respirator when ventilation is inadequate. Empty containers retain
product residue and can be hazardous.
7. Handling and storage
Handling
Storage
:
:
norflurane
AIHA WEEL (United States, 10/2011).
TWA: 1000 ppm 8 hours.
ethanol
ACGIH TLV (United States, 6/2013).
STEL: 1000 ppm 15 minutes.
NIOSH REL (United States, 4/2013).
TWA: 1900 mg/m³ 10 hours.
TWA: 1000 ppm 10 hours.
OSHA PEL (United States, 2/2013).
TWA: 1900 mg/m³ 8 hours.
TWA: 1000 ppm 8 hours.
OSHA PEL 1989 (United States, 3/1989).
TWA: 1900 mg/m³ 8 hours.
TWA: 1000 ppm 8 hours.
CARBON DIOXIDE
ACGIH TLV (United States, 2000).
STEL: 54000 mg/m³ 15 minutes.
STEL: 30000 ppm 15 minutes.
TWA: 9000 mg/m³ 8 hours.
TWA: 5000 ppm 8 hours.
NIOSH REL (United States, 2000).
STEL: 54000 mg/m³ 15 minutes.
STEL: 30000 ppm 15 minutes.
TWA: 9000 mg/m³ 10 hours.
TWA: 5000 ppm 10 hours.
OSHA PEL (United States, 1993). Notes:
TWA: 9000 mg/m³ 8 hours.
TWA: 5000 ppm 8 hours.
8. Exposure controls/personal protection
Ingredient
Exposure limits
4/11
1611
2/5/2014.