Exposure controls/personal protection, Physical and chemical properties, Stability and reactivity – Chemtronics Electro-Wash PR ES1603 User Manual

Page 7: Toxicological information

Advertising
background image

Electro-Wash® PR

8. Exposure controls/personal protection

Safety eyewear complying with an approved standard should be used when a risk
assessment indicates this is necessary to avoid exposure to liquid splashes, mists or
dusts. If contact is possible, the following protection should be worn, unless the
assessment indicates a higher degree of protection: chemical splash goggles.
Personal protective equipment for the body should be selected based on the task being
performed and the risks involved and should be approved by a specialist before
handling this product.
When there is a risk of ignition from static electricity, wear anti-static protective clothing.
For the greatest protection from static discharges, clothing should include anti-static
overalls, boots and gloves.

Eyes

Skin

:

:

Environmental exposure
controls

:

Emissions from ventilation or work process equipment should be checked to ensure
they comply with the requirements of environmental protection legislation. In some
cases, fume scrubbers, filters or engineering modifications to the process equipment
will be necessary to reduce emissions to acceptable levels.

Liquid. [Aerosol.]

0.67

>1 [Air = 1]

32.9 kPa (247 mm Hg) [room temperature]

Mild. Hydrocarbon.

Colorless.

>1 (butyl acetate = 1)

9. Physical and chemical properties

Physical state

Relative density
Vapor pressure
Vapor density
Evaporation rate

Odor

Color

:

:
:
:
:
:
:

Flash point

:

Closed cup: <-18°C (<-0.4°F)

Flammable limits

:

Lower: 1.2%
Upper: 7%

Type of aerosol

:

Spray

Heat of combustion

:

29.59 kJ/g

Aerosol product

The product is stable.

Reactive or incompatible with the following materials: Alkaline. Strong oxidizing materials
Under normal conditions of storage and use, hazardous decomposition products should
not be produced.

Avoid all possible sources of ignition (spark or flame). Do not spray on a naked flame or
any incandescent material. Do not pressurize, cut, weld, braze, solder, drill, grind or
expose containers to heat or sources of ignition. open flames, sparks and static
discharge

10. Stability and reactivity

Chemical stability

Conditions to avoid

Incompatible materials
Hazardous decomposition
products

:
:

:
:

Possibility of hazardous
reactions

:

Under normal conditions of storage and use, hazardous reactions will not occur.

11. Toxicological information

Acute toxicity

acetone

LD50 Oral

Rat

5800 mg/kg

-

n-hexane

LC50 Inhalation Gas.

Rat

48000 ppm

4 hours

LD50 Oral

Rat

15840 mg/kg

-

Product/ingredient name

Result

Species

Dose

Exposure

Conclusion/Summary

:

Not available.

Chronic toxicity

7/12

3991

7/22/2013.