11. Toxicological information

Conclusion/Summary

:

Not available.

Teratogenicity

Conclusion/Summary

:

Not available.

Reproductive toxicity

Conclusion/Summary

:

Not available.

12. Ecological information

Ecotoxicity

:

No known significant effects or critical hazards.

Aquatic ecotoxicity

acetone

Acute EC50 20.565 mg/l Marine water

Algae - Ulva pertusa

96 hours

Acute LC50 6000000 µg/l Fresh water

Crustaceans - Gammarus pulex

48 hours

Acute LC50 10000 µg/l Fresh water

Daphnia - Daphnia magna

48 hours

Acute LC50 100 mg/l Fresh water

Fish - Pimephales promelas -
Juvenile (Fledgling, Hatchling,
Weanling)

96 hours

Chronic NOEC 4.95 mg/l Marine water

Algae - Ulva pertusa

96 hours

Chronic NOEC 0.1 ml/L Fresh water

Daphnia - Daphnia magna -
Neonate

21 days

methanol

Acute EC50 16.912 mg/l Marine water

Algae - Ulva pertusa

96 hours

Acute EC50 10000000 µg/l Fresh water

Daphnia - Daphnia magna

48 hours

Acute LC50 2500000 µg/l Marine water

Crustaceans - Crangon crangon -
Adult

48 hours

Acute LC50 100 mg/l Fresh water

Fish - Pimephales promelas -
Juvenile (Fledgling, Hatchling,
Weanling)

96 hours

Chronic NOEC 9.96 mg/l Marine water

Algae - Ulva pertusa

96 hours

n-hexane

Acute LC50 113000 µg/l Fresh water

Fish - Oreochromis
mossambicus

96 hours

Product/ingredient name

Species

Result

Exposure

Conclusion/Summary

:

Not available.

Persistence/degradability

Conclusion/Summary

:

Not available.

Other adverse effects

:

No known significant effects or critical hazards.

The generation of waste should be avoided or minimized wherever possible. Disposal
of this product, solutions and any by-products should at all times comply with the
requirements of environmental protection and waste disposal legislation and any
regional local authority requirements. Dispose of surplus and non-recyclable products
via a licensed waste disposal contractor. Waste should not be disposed of untreated to
the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Waste packaging should be recycled. Incineration or landfill should only be considered
when recycling is not feasible. This material and its container must be disposed of in a
safe way. Empty containers or liners may retain some product residues. Do not
puncture or incinerate container.

Waste disposal

13. Disposal considerations

Disposal should be in accordance with applicable regional, national and local laws and regulations.

:

United States - RCRA Toxic hazardous waste "U" List

Acetone (I); 2-Propanone (I)

67-64-1

Listed

U002

Methanol (I); Methyl alcohol (I)

67-56-1

Listed

U154

Ingredient

CAS #

Status

Reference
number

9/13