001 g/g, 0015 g/g, None detected – Chemtronics Poly-Wipes 6259HC User Manual

Page 2: 021 g/g, Poly-wipes test data, Distributed by, Technical and application assistance

Advertising
background image

Poly-Wipes Test Data

TECHNICAL HOT LINE 1-800-TECH-401



Wipe Material

Polyester Knit Fabric (70 denier)


Wipe

6200 Series

6250B Series

6250 Series

6250LE Series


Availability

9”x9” (6209)

6”x6”(6256B)

4" x 4" (6254)

9" x 9" (6259)

9" x 9"(6259LE)

Basis Weight

125 g/m

2

(+/- 5 g/m

2

)

143 g/m

2

(+/- 5 g/m

2

)

143 g/m

2

(+/- 5 g/m

2

)

140 g/m

2

(+/- 5 g/m

2

)

Particle Counts (LPC)
>/= 0.5 microns

11 million/m

2

17 million/m

2

12 million/m

2

9.2 million/m

2


NVR in DI water

None Detected

None Detected

0.053 g/g

None Detected


NVR in IPA

None Detected

None Detected

0.22 g/g

None Detected

FTIR : silicone, amide,
phthalates

None Detected

None Detected

None Detected

None Detected

Chloride Ions

None Detected

0.001 g/g

0.007 g/g

None Detected

Flouride Ions

None Detected

None Detected

Nitrite Ions

None Detected

None Detected

Nitrate Ions

None Detected

None Detected

Phosphate Ions

None Detected

None Detected

Sulphate Ions

None Detected

0.004 g/g

0.001 g/g

0.001

Sodium Ions

0.001 g/g

0.001

Calcium Ions

0.0015 g/g

0.0012

Zinc Ions

None Detected

None Detected

Ammonium

0.021 g/g

None Detected

None Detected

Absorbency

365 ml/m

2

412 ml/m

2

412 ml/m

2

410 ml/m

2


The wipe tests were done using the recommended practices of the Institute of Environmental Science, Swabs
and Wipes Working Group.

TECHNICAL AND APPLICATION
ASSISTANCE

Coventry

 Clean Room Products provides

A technical hotline to answer your technical
And application related questions.

The toll free number is:

1-800-TECH-401