Pro-Link DISINFECTANT SPRAY RA008 EN User Manual
Page 4

Chemical stability
Material is stable under normal conditions.
Possibility of hazardous
reactions
Hazardous polymerization does not occur.
Conditions to avoid
Avoid temperatures exceeding the flash point.
Hazardous decomposition
products
No hazardous decomposition products are known.
11. Toxicological information
Information on likely routes of exposure
Ingestion
Expected to be a low ingestion hazard.
Inhalation
No adverse effects due to inhalation are expected.
Skin contact
Not available.
Eye contact
Causes serious eye irritation.
Symptoms related to the
physical, chemical and
toxicological characteristics
Direct contact with eyes may cause temporary irritation.
Information on toxicological effects
Acute toxicity
Test Results
Components
Species
Butane (CAS 106-97-8)
LC50
Mouse
Inhalation
Acute
680 mg/l, 2 Hours
Rat
658 mg/l, 4 Hours
Ethyl Alcohol (CAS 64-17-5)
LC50
Mouse
Inhalation
Acute
39 mg/l, 4 Hours
Rat
20000 mg/l, 10 Hours
LD50
Dog
Oral
5.5 g/kg
Guinea pig
5.6 g/kg
Mouse
3450 mg/kg
Rat
6.2 g/kg
LD50
Mouse
Other
933 mg/kg
Rat
1440 mg/kg
o-Phenylphenol (CAS 90-43-7)
LD50
Cat
Dermal
Acute
500 mg/kg
LD50
Cat
Oral
500 mg/kg
Guinea pig
3500 mg/kg
Mouse
2000 mg/kg
Rat
> 1000 mg/kg
LD50
Mouse
Other
50 mg/kg
Propane (CAS 74-98-6)
LC50
Rat
Inhalation
Acute
> 1442.847 mg/l, 15 Minutes
658 mg/l/4h
4 / 8
Product name: Disinfectant Spray for Hospital Use
Product #: 0881, 1000006974, 1000006973, 1000007011, 1000006976, 1000007214, 1000007838 Version #: 02 Revision date: 06-13-2014 Issue date: 05-01-2014