Material safety data sheet – Pro-Link MiniAire Refills - All Fragrances MA07-30R EN User Manual

Page 2

Advertising
background image

MATERIAL SAFETY DATA SHEET

___________________________________________________________________________________

Date of last change 22/03/10

Page 2 of 4





Auto Ignition Temperature (ºC)

204-465

Special Procedures

Water from fogging nozzles may be used to cool closed
containers to prevent build up if exposed to extreme
temperatures. Full protective equipment including self
contained breathing apparatus should be worn in a fire
involving this material.

Flammability Flammable
If yes, under which conditions?

Excessive heat, sparks and open flame

Extinguishing media

Water, Carbon Dioxide, Dry Chemical, Foam

Upper Flammable limit (% by volume)

23.5

Lower Flammable limit (% by volume)

1.2

Explosion Data – Sensitivity to static
discharge

Not Applicable

Explosion Data – Sensitivity to impact

Not Applicable

Hazardous combustion – Products

Hygdrocarbon fumes and smoke. Carbon Monoxide where
combustion is incomplete.

Aerosol flame projection – classified as:

15 – 45 cm

Aerosol flame projection – flashback:

None

Flash Point (ºC), Tag Closed-Cup
(Concentrate)

Lowest known value is acetone @ -18ºC





Leak/spill

Remove all sources of ignition. Use an inert absorbent material, and
non-sparking tools. Ventilate area. Prevent from entering a
watercourse.





Storage Needs

Keep away from heat, sparks, and open flames

Engineering controls

Ventilation – Local (Mechanical if used indoors on a continuous basis)

Handling Procedures and
Equipment

Store in a cool, well ventilated area not to exceed 50 deg. C

Synergistic Materials

None known





Gloves / Type

Not normally required

Respiratory / Type

Not normally required

Eye / Type

Safety Glasses

Footwear / Type

Not normally required

Other / Type

Not required

5. FIRE

FIGHTING

METHODS

6. ACCIDENTAL

RELEASE

MEASURES

7. HANDLING

&

STORAGE

8.

EXPOSURE CONTROLS / PERSONAL PROTECTION

Advertising