None normally required unless misting occurs, then use a NIOSH approved respirator.
Respiratory Protection:
Rubber Gloves
Skin Protection:
Safety Glasses or Goggles
Eye Protection:
Chemical apron when handling large volumes of material.
Other:
Local exhaust to keep below any listed TLV.
Ventilation Requirements:
Liquid
Physical Form:
Clear
Color:
Amine
Odor:
212°F
Boiling Point:
Same as water.
Evaporation Rate:
12.0 ± 0.5
pH:
0.99
Specific Gravity:
100%
Solubility:
NE
Freezing Point:
98.5%
% Volatile:
This product is stable at ambient temperature and pressure.
Stability:
None
Hazardous Decomposition Products:
None
Hazardous Polymerization:
Oxidizing materials, strong acids
Incompatibility:
Page: 3 of 4
11/28/06
Diplomat
Section 8 - Exposure Controls Personal Protection
Section 9 - Physical / Chemical Properties
Section 10 - Stability and Reactivity
NE
Vapor Pressure:
15%
V.O.C.