CP 52 - REAR PANEL

ቢ Chassis Ground Screw provides a convenient earth (technical) ground connection point. The CP 52 does not ground the

chassis through the power cord. It is important that the unit be grounded.

ባ POWER jack accepts the cable from a Rane RS 1 remote power supply (included) or an optional Rane RAP 10 power

supply. This is not a telephone jack. Use of a supply not approved by Rane may damage the unit and void the warranty.

ቤ ZONE REMOTE Port provides the wiring interface for the optional ZR 1 wired remote. The ZR 1 remote provides remote

control of Zone Level and Zone Program Select functions. Refer to page Manual-5 for details.

ብ ZONE OUTPUT Port features a balanced cross-coupled line driver with a Euroblock connector. These Left and Right

Outputs may be wired balanced or unbalanced.

ቦ MONO switch, when pressed in, sums the left and right signals to provide a mono Zone signal available at both Left and

Right Outputs.

ቧ ZONE EXPAND Port features a balanced cross-coupled line driver with a Euroblock connector. This mono Output may be

wired balanced or unbalanced.

ቨ ZONE EXPAND switch assigns PAGE-only, PROGRAM-only or full ZONE (both) as the source for the Expand Output.

ቩ ZONE EXPAND LEVEL trim adjusts the signal level delivered to the ZONE EXPAND OUTPUT.

ቪ PRIORITY RELEASE TIME control sets the delay time from last detected signal to release of automatic priority over-

ride. The range of control is 5 seconds (ccw) to 20 seconds (cw).

ቫ PRIORITY OFF/ON switch allows disabling the automatic priority override function when in the OFF position.

ቭ PRIORITY DETECT THRESHOLD control allows adjusting the threshold from -

∞

(signal on) to -35 dBu (typ). The

factory setting is -50 dBu.

ቮ Four PROGRAM INPUTS are provided. Three are non-priority Inputs. The fourth is a Program PRIORITY Input. When

signal is detected at this Input, it is automatically selected as the Program Input source regardless of the front panel PRO-
GRAM SELECT setting.

ቯ PAGE LEVEL TRACKS ZONE LEVEL switch, when ON, forces the Paging level to track the Zone level. When OFF,

Paging level and Zone level are independent.

ተ HIGH/LOW CUT FILTER switch, when IN, limits the bandwidth of the Paging Input from 100 Hz to 7 kHz, improving

intelligibility in some installations. The Paging detector is always bandlimited to 100 Hz to 7 kHz.

ቱ PHANTOM POWER switch, when ON, enables +15 volt Phantom Power to the PAGING INPUT Euroblock. If the front

panel LINE switch is selected, Phantom Power is defeated.

ቲ PAGING INPUT Euroblock connector may be wired balanced or unbalanced.