Rane ECM 64 User Manual

Page 21

Advertising
background image

Manual-21

Hybrid Parameter List (HPL)
Hybrid Command

Data

Description

0

Dial DTMF Number

(char) string

Null terminated ASCII string, 20 (char) max

1

Dial Stored Number

1-6

Dial stored number (1 – 6)

2

Off Hook

1/0

1= Off Hook / 0 = On Hook

A ‘,’ within the DTMF number inserts a 1 second delay.
A non-digit within the DTMF number is allowed for separation (425.355.6000).
For Rev 1.2 or greater there are added special function DTMF dialing operators:
Operator
!1

Performs a 100 ms Flash Hook

!2

Performs a 500 ms Flash Hook

!3

Places the caller on Hold

!4

Removes the caller from Hold

Send Hybrid Command (92 hex)
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $XX (where $XX = number of data bytes to follow including checksum)
Transmit $92 (command code)
Transmit Hybrid command
Transmit Data
Transmit the checksum
Get COMSTAT

Send MRP Table (93 hex)
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $12 (where $12 = number of data bytes to follow including checksum)
Transmit $93 (command code)
Transmit 16 byte table
Transmit the checksum
Get COMSTAT

Get OPSTAT (00 hex):
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $02 (where $02 = number of data bytes to follow including checksum)
Transmit $00 (command code)
Transmit $FE (checksum)
Get STATUS
Get Checksum
Get COMSTAT

Advertising