Manual-16 – Rane SR 4 User Manual
Page 16

Manual-16
Cable Type 2
4 twisted pair unshielded CAT 5, Belden #1583(A, B, E, ENH, R)
4 twisted pair shielded CAT 5, Belden #1624 (P, R)
4 twisted pair unsheilded CAT 5, Belden #1700 (A, R)
Max Distance
for Cable (feet)
Max Distance for
Cable (meters)
Number of
SR 4 Remotes
Vs = 15V
RPM 44
RPM 22
1000
305
1
1000
305
2
1000
305
3
1000
305
4
1000
305
5
1000
305
6
1000
305
7
952
290
8
Vs = 12V
RPM 88
1000
305
1
1000
305
2
1000
305
3
1000
305
4
919
280
5
778
237
6
674
205
7
595
181
8
Vs = 8V
671
205
1
403
123
2
288
88
3
224
68
4
184
56
5
156
47
6
135
41
7
119
36
8
Note: This table is only for systems using SR 4 remotes (all remotes on 485 bus are
the same). For mix and match calculation of SR 2, SR 3 and SR 4 Remotes, use the
SRCABLELENGTH.XLS Microsoft Excel™ spreadsheet on the Drag Net CD-ROM or
at www.rane.com/sr4.html.
Requires
external
supply