Troubleshooting – Chamberlain 1025 User Manual

Page 7

Advertising
background image

7

Problem

Remedy

LCD display is blank.

• Power not connected; check plug and wires.
• ACRx 2 is broken; repair or replace.

LCD display is on but ACRx 2 does not function properly.
•
Turn power off, then on again.

• Check 24V/12V jumper.

All users have short radio range, green light is flashing.
•
A transmitter is stuck on. Use M-18 test set to locate and disable transmitter.

All users have short radio range, green light is off.

• Radio interference; try moving antenna location.

A single user has short radio range.

• Replace transmitter battery, or move transmitter to a

different place in car.

A single user cannot obtain access. Green light
on ACRx 2 flashes, LCD message does not change.

• Repeat the Add User routine.

A single user cannot obtain access. Green light

• Replace transmitter battery, or replace and

reprogram
on ACRx 2 does not flash.

transmitter.

When Grant Access button is pushed, ACRx 2 relay
clicks but door/gate does not open.

• Check door operator and wiring.

ACRx 2 prints incorrect time/date.

• Time or date is wrong. Do Set Time or Set Date

routine.

• Clock backup battery needs replacement.

No users can access ACRx 2, LCD display is on.

• ACRx 2 must be in the idle state, with time and date

displayed. Press SETUP/EXIT, or cycle power to
ACRx 2.

SERVICE INFORMATION TOLL FREE NUMBER (U.S.A.): 1-800-588-2806

IN CANADA: 1-800-654-4736

TROUBLESHOOTING

Advertising