Whenever the alarm is operating, the green Power LED flashes every 30
seconds to indicate the unit is monitoring for CO. If the alarm senses
dangerous levels of CO, the red Alarm LED will flash and the alarm will
emit an audible alarm pattern.

5. Model KN-COB-B-LPM Operating Characteristics

Operating and Alarm Characteristics

Function

LED Display

Alarm Sound

Unit Status

Recommendation

Normal
Operation

Green LED
flashes every 30
seconds

None

Normal DC
operation (sensing
no CO) and with
good batteries

None

Carbon
monoxide
alarm

Red LED flashes
with beeps.

4 quick beeps,
5 seconds
silence,
repeating

Alarm condition.
Dangerous con-
centrations of CO
detected

Refer to “What to
do When the Alarm
Sounds” (inside front
cover)

Low
battery

Red LED flashes
every 60 seconds

One quick
beep every
60 seconds

Batteries need to be
replaced

Replace all three AA
batteries

Error /
service
alarm

Red LED flashes
every 30 seconds

One quick
beep every
30 seconds

Unit is in error
condition

Error

Red LED
constantly on

Constant
alarm

Very low battery or
unit malfunction

Replace battery.
If condition continues,
unit has malfunc-
tioned. Replace
immediately. Unit will
not respond to CO

Normal
Test/Reset
function

Red LED flashes
with beeps.

4 quick beeps,
5 seconds
silence,
repeated once

Normal operation
when Test/Reset
button is pressed

CO not detected.
Alarm for test pur-
poses only

End of
unit life
indicator

Red LED flashes
two times
every 30 seconds

Two quick
beeps every
30 seconds

End of unit life

Replace unit imme-
diately. Unit will not
respond to to CO

6. Model KN-COPP-B-LPM (with digital display)
Operating

Characteristics

When the unit is first powered up, the green Operate LED flashes
once every 30 seconds and the digital display will show three “eights”
– indicating the alarm is in the start-up mode. The three “eights” will
remain for approximately 30 seconds. Then, the alarm will display “0”
and begin monitoring the air for CO and will continue to do so as long
as it receives power.

This alarm will display a “0” if CO concentrations between 0 and 30
PPM have been detected within the last 15 seconds.