Beckett, 12 vdc oil igniter – Beckett 61828 12V Oil Igniter User Manual
Page 2
R.W.
BECKETT
CORPORATION
P.O. Box 1289, Elyria, Ohio 44036
R.W. BECKETT CANADA, LTD
430 Laird, Unit 3, Guelph, Ontario, N1G 3X7
12 Vdc Oil Igniter
Table 2 - Igniter Base Plate Bill of Materials
Part No.
Burner Models
Baseplate
Gasket
Baseplate
Igniter
Gasket
Barrier
Gasket
5218301U
Beckett ADC 12 Vdc
31405
51780BK
32743
32301*
5218303U
Beckett SDC 12 Vdc
31481
51855BK
32743
n/a
5218307U
Wayne ‘M’ Models for 12 Vdc
n/a
51899BK
n/a
n/a
5218305U
Wayne ‘E’ Models for 12 Vdc
n/a
21847
n/a
n/a
* 32301 Barrier Gasket is used only on Beckett Model ADC.
Figure 1 - Igniter Assembly Components (5218301U shown. Other models will have different baseplates and terminals.)
Baseplate Gasket
Baseplate
Igniter
Mounting Screws
3241101 Igniter Gasket
(Between baseplate and igniter)
Igniter Input (+) Blue-White Striped Lead
Field Installed Cad Cell
(if applicable)
Barrier Gasket
Yellow Leads For Cad Cell Connection -
Interrupted Ignition Without Primary Control
The Yellow leads from the igniter will NOT be used and shall
be wire nutted individually and placed in the housing wiring
compartment.
Verify the igniter secondary output terminals are correctly
arranged to make good electrical contact with the oil burner
electrodes.
16.
17.
Igniter Input (+) Solid White Spark Control Lead
Igniter Input (-) Black Lead for Ground
Yellow Cad Cell Leads
Close the igniter. Install and securely tighten the two front
base plate retaining screws (4 screws, if no hinge).
Reconnect electric power to the burner circuit.
Verify with instruments that the burner is adjusted to the
manufacturer’s recommended settings
Cycle the burner several times to verify prompt and smooth
ignition. Verify proper operating and limit control operation
before leaving.
18.
19.
20.
21.