CANOGA PERKINS 3240S SNMP-Managed T1/E1 Fiber-Optic Multiplexer User Manual

Page 38

Advertising
background image

EdgeAccess

To run I/O port loopback in software, follow these steps:

1. From the Main Menu, type

2

, "Multiplexer Configuration/Status," and press <Enter>.

2. At the Multiplexer Configuration/Status screen, type

2

, "I/O port Module & Logical Address,"

and press <Enter>, then at the prompt, type the unit and slot number.

3. At the Unit and Slot Configuration screen, type 3, "Set/Clear Port Loopback," and then at the

prompt, enter the unit and port number.

4. To start (activate) Local or Remote Loopback for the selected port, type

2

or

3

and press <Enter>;

loopback starts.

5. To stop Loopback, type

1

and press <Enter>.

6. To return to the Main Menu, press <Esc>.

To run composite loopback manually, follow these steps:

1. At the rear panel, set the System Mode switch to LOC for local loopback or to REM for remote

loopback; loopback starts automatically.

2. To stop Loopback, set the System Mode switch to NORM.

To run composite loopback in software, follow these steps:

1. From the Main Menu, type

2

, "Multiplexer Configuration/Status," and press <Enter>.

2. At the Multiplexer Configuration/Status screen, type

1

, "System Configuration/Status," and press

<Enter>.

3. At the System Configuration/Status screen, type 1, "Set/Clear Composite Loopback," press

<Enter>; loopback starts.

4. To stop Loopback, type

1

and press <Enter>.

5. To return to the Main Menu, press <Esc>.

4-6 3240S Fiber-Optic Multiplexer