2.2.3 Loss Budget

The maximum possible distances with the standard versions is dependent on the
overall optic loss over the fiber optic link. This is called the "loss budget." The loss
budget is determined by comparing the launch power at the modem with receiver
sensitivity at the other end of the link. The differential is the loss budget. Refer to
Table 2-A for 2262 loss budgets.

Table 2-A.

2262 Loss Budgets

NOTE: To measure the optical power, data must be present at the

data input leads.

850nm 1310nm

LED Laser
Cable Standard

62.5/125 15

8-10/125 N/A 20

N/A

2.3 Stand Alone Installation

Installing the stand alone version of the 2262 modem is straightforward. It should
be located convenient to the operator, but the electrical and optical cables should
be isolated from foot traffic to prevent possible damage to the fiber optics. See
Figure 2-1 for available rear panel configurations.

The main components of the 2262 are the following:

AC/DC Power

Interface Connectors

Alarm Relay Connectors

E1 Impedance Switch

Loopback Switch (front panel)

Figure 2-1 shows the rear panel configurations available for T1 applications.

Figure 2-2 shows the rear panel configurations available for E1 applications.