EdgeAccess Universal Chassis System

Model 1202 CIM User Manual

2-2

All modules in the chassis supply their alarm status to the alarm relay contacts on the CIM. You
can connect an external device to the terminal to provide alarm information to a person or an
environment away from the chassis.

6. Connect devices to collect alarm information for Major and Minor alarms. The alarm

contacts are located on the front panel; see Figure 2. The relay alarm contacts provide both
normally open and normally closed contacts for each port:

NO The contacts are open for normal operation and closed in a fault condition

COM The electrical common

NC The contacts are closed for normal operation and open in a fault condition

2.3

Front Panel Controls

The front panel of the CIM includes four LEDs that show current status, contacts for alarm
outputs, and an Alarm Acknowledgment pushbutton.

2.3.1 LEDs

Figure 2 shows the four LEDs on the front panel; Table 1 describes them.

Table 1. Front Panel LEDs

LED

State

Definition

CLK (Clock)

Green

This CIM is providing the active clock source for the management bus

Off

This CIM is not the clock source

STA (Status)

Green

Normal operation

Amber

This alarm relay is latched with a major and/or minor alarm

Red

Fault in the CIM

MAJ (Major)

OFF

No major alarms

Red

A major alarm in the CIM or the chassis

MIN (Minor)

OFF

No minor alarms

Amber

A minor alarm in the CIM or the chassis

Note: When an alarm occurs in a multiple chassis configuration, only the chassis that generates

the alarm shows the amber STA LED.