Login and main menu – CANOGA PERKINS 2345 T3 Fiber Optic Modem User Manual

Page 20

Advertising
background image

EdgeAccess Universal Chassis System

Model 2345 User Manual

3-4

Login and Main Menu

When you connect directly to the 2345 or to the DMM through HyperTerminal or Telnet, the first
screen is the Login Menu. To log in, follow these steps:

1. If this is your initial setup and no username or password has been set, type

admin

and press

<Enter> at the prompts for the username and password. Otherwise, type your username and press
<Enter>, then type your password and press <Enter>.

2. If you are using a DMM, the Main Menu for the DMM appears after you log in. This is the main

management screen for the DMM. For details on all menu options, see the user manual for your
DMM. From this screen, access the 2345 by either of two methods.

• To reach the 2345 directly, follow these steps:

a. Type 4, "Manage or access a specific Module," and press <Enter>.

b. Type the slot and chassis numbers with a slash, such as "

1/4

" for chassis 1, slot 4, and then

press <Enter>.

c. At the Module Menu, type

4

, "Access User Interface," then press <Enter> to reach the Main

Menu for the 2345.

• To reach the chassis, and then select the 2345, follow these steps:

a. Type

3

, "Manage or access a specific Chassis," and press <Enter>, press <Space> to cycle

between the chassis in the domain, and then press <Enter> to select the chassis.

b. At the Chassis Management screen, press <Space> to cycle to the slot number for the 2345,

then press <Enter> to reach the Main Menu for the 2345.

You can reach all configuration options from the Main Menu; see Table 4.

Table 4. Main Menu Selections

Menu Item

Description

1. System Configuration

View and set values for the system information and
communications parameters

2. Diagnostics

Set up loopback for local and remote devices

3. Performance Monitoring

View statistics related to RFC 2496 or G.826 standards

4. Link Error Counters

View number of errors that occur on the link

5. System Alarms

View current conditions for local and remote alarms

6. Utilities

Set up managing hosts for accessing the DMM and
receiving traps

7. Software Update

Download and install new firmware