Figure 22. ip/snmp agent configuration screen -12 – CANOGA PERKINS L357 Gigabit Ethernet Service Unit User Manual

Page 32

Advertising
background image

EdgeAccess Universal Chassis System

L357 Gigabit Ethernet Service Unit

4-12

IP/SNMP AGENT CONFIGURATION

Local

Remote

MAC Address

00 40 2A 00 87 E3

00 40 2A 00 53 E7

Management Port

UP

UP

1)

Ethernet IP Address

172.016.148.030

172.16.143.10

Subnet Mask

255.255.000.000

255.255.0.0

Default Gateway

000.000.000.000

172.16.1.1

2)

SLIP/PPP IP Address

000.000.000.000

192.0.0.83

3)

Serial Port Config

VT100

VT100

4)

BOOTP

Disabled

Disabled

5)

Telnet Security

Disabled

Disabled

6)

Host Table

7)

Trap Table

8)

Inband Management Port

Both Ports

9)

Management VLAN

Disabled

10) Management VLAN Number

1

Figure 22. IP/SNMP Agent Configuration Screen

Table 7. SNMP Configuration Parameters Description

Item

Description

1) Ethernet IP Address
Subnet Mask
Default Gateway

Enter the IP address for access through the Ethernet network, the
mask that sets the network ID part of the IP address, and the address
of the network node that connects to another network

2) SLIP/PPP IP Address

Enter the IP address for access through SLIP or PPP

3) Serial Port Config

Set the type of serial port connection: VT100, SLIP, or PPP

4) BOOTP

Enable this if the module needs to obtain its IP address from a
BOOTP server; when the unit has an IP address, disable BOOTP

5) Host Table

Access the Host Table screen (for standalone enclosure, only)

6) Trap Table

Access the Trap Table screen (for standalone enclosure, only)

8) Inband Management
Port

Set the port that will receive management packets; can be Ext. only,
User only, Both ports, or No Management

9) Management VLAN

Enable or disable the Management VLAN

10) Management VLAN
Number

Set the number for the VLAN; range is 0-4095

Advertising