4.6.2 Remote Connectivity Loss Detection

The Connectivity Loss Detection (CLD) feature enables you to detect loss of connectivity between
two N525s in a point-to-point circuit, and to detect undesired link performance. It is possible to
remotely configure N525 CLD parameters using the SideBand management channel from an L351.
See the diagram below.

Figure 4-29. N525 to N525 Connectivity Loss Detection

In conjunction with CLD you can use Connection Loss Forwarding (CLF), which will shut down the
User port on an N525 if there is a loss of connectivity between the N525 Extension ports. CLD and
CLF are disabled by default.

POP A

SNMP

Fibre

N525

L351

In UCS1002

POP Z

Fibre

N525

Customer

Premise Z

L351

In UCS1002

SNMP

---------------------------REMOTE LATENCY/JITTER TEST-----------------


Test IP Addr/VLAN 0.0.0.0/0 Round Trip Packets 0
Test Duration 00:00 Dropped Packets 0
Minimum Latency (ms) 0.000000 Minimum Jitter (ms) 0.000000
Average Latency (ms) 0.000000 Average Jitter (ms) 0.000000
Maximum Latency (ms) 0.000000 Maximum Jitter (ms) 0.000000

(1) To IP Addr 0.0.0.0 (5) DF Bit Clear
(2) From IP Addr Auto Selection (6) DSCP Precedence Best Effort
(3) Test VLAN 0 Drop Probability Not Used
(4) Test Packets per sec 1 (7) Test Packet Priority (0-7) 0

(8) Test Duration min:sec (0=forever) 0
(9) Min Test Payload Size (40 - 1954) 40
(10) Max Test Payload Size (40 - 1954) 40
(11) Test Packet Timeout sec (1 - 10) 3
(12) Start Remote Test
(13) Stop Remote Test

Select [1-13]: