EdgeAccess Universal Chassis System

If the firmware on the L351 is outdated, you need to upgrade it. If the L351 is in a chassis or 1030
enclosure within a domain with a DMM, go to the User Manual for the DMM and use that procedure
to install the new software. If the L351 is in a Model 1020, follow these steps:

1. TFTP server should be open and running.

2. From the Main Menu, type 7, Software Upgrade, and press <Enter>.

3. At the Software Upgrade menu, type 4, Get New File with TFTP, and press <Enter>.

4. At the prompts, type the IP address for the TFTP server and the File Name.

5. At the prompt, type Y to transfer the file and start the upgrade.

To upgrade a remote unit to the same version of software, follow these steps:

1. From the Main Menu, type 7, Software Upgrade, and press <Enter>.

2. At the Software Upgrade menu, type 3, Copy Software from Source unit to Destination unit,

and press <Enter>.

3. At the prompt, select the Source, which is the inactive bank for the local module, then select

the Destination, which is the inactive bank for the remote module, and press <Enter>; the
upgrade runs automatically.

To run the new software, swap banks, and reset the module, follow these steps:

1. From the Main Menu, type 7, Software Upgrade, and press <Enter>.

2. At the Software Upgrade menu, type 2, Swap Bank, press <Tab> to highlight the Remote

column, and press <Enter>.

3. Type 2, Swap Bank, check that the Local column is highlighted, and press <Enter>. Both

modules reset and start using the new firmware.

L351 10/100BASE Media Converter