EdgeAccess Model 1020

3

Model 1020 Standalone Enclosure User Manual

The Model 1020 standalone enclosure, shown in Figure 1, supports one 2U-sized module that is
managed through either SNMP or Sideband Management Control (SBMC).

Figure 1. Model 1020 Standalone Enclosure

The front provides three switches, three LEDs, two connectors, and a slot for a managed module. The
back includes an AC power cord socket. The AC power supply provides +5 VDC to the module.

Switch

Setting

Selects

MDM/TRM for EIA-232 port

MDM

DTE terminal for SLIP

TRM

DCE terminal for VT100

F1/NRM/F2, typically for Loopback for the module

F1

Local loopback, typically

Note: Set to NRM except to isolate a fault.

NRM

Normal operation

F2

Remote loopback, typically

HDX/FDX for 10BASE-T port

HDX

Half duplex

FDX

Full duplex

Note: If the link partner is set to auto-negotiation, the link uses 10M and follows the HDX/FDX

switch setting for this port; otherwise, set this switch to match the other switch on the link.

LED

State

Definition

PWR

Off

No power

Green

Power is on

Tx for 10BASE-T port

Off

No transmission

Green blinking

Transmission activity

LNK/Rx for 10BASE-T port

Off

No link

Green

Link is established at full duplex

Amber

Link is established at half duplex

Blinking

Data is received