Alarms – CANOGA PERKINS 9161 Network Interface Device User Manual

Page 13

Advertising
background image

9161 Network Interface Device

2-3

Table 1. 9161 Management LEDs

LED Status

Description

Off

No power/power supply not installed

Green Normal

operation

Amber System

self-test

P1 (Primary) or

P2 (Secondary) Power

Red

Power failure/Major alarm

Green Normal

operation

Amber

System self-test/one fan failed

Red

More than one fan failed

Fans

Red blinking

Fan not installed

Off No

power

Green Normal

operation

Green blinking

Management traffic

Amber System

self-test/over-temperature

Amber blinking Management traffic with over-temperature

Management

Red

Diagnostic or CPU failure

Table 2. 9161 Interface LEDs

LED Status

Description

Off

No transmission activity

Green blinking

Transmission activity

Amber System

self-test

TX

Red

Port disabled; may be due to Link Loss Forwarding (LLF)

Off No

link

Green Link

established

Green blinking

Receiving activity

Amber System

self-test

RX

Red

Receiving Remote Fault

Off Non-network

connection

Green Network

connection

NET

Amber System

self-test

Alarms

The 9161 can generate Traps and Major and Minor Alarms. For details about the Traps Log and
setting up notification, see Chapter 4.