Alarms – CANOGA PERKINS 9161 Network Interface Device User Manual
Page 13
9161 Network Interface Device
2-3
Table 1. 9161 Management LEDs
LED Status
Description
Off
No power/power supply not installed
Green Normal
operation
Amber System
self-test
P1 (Primary) or
P2 (Secondary) Power
Red
Power failure/Major alarm
Green Normal
operation
Amber
System self-test/one fan failed
Red
More than one fan failed
Fans
Red blinking
Fan not installed
Off No
power
Green Normal
operation
Green blinking
Management traffic
Amber System
self-test/over-temperature
Amber blinking Management traffic with over-temperature
Management
Red
Diagnostic or CPU failure
Table 2. 9161 Interface LEDs
LED Status
Description
Off
No transmission activity
Green blinking
Transmission activity
Amber System
self-test
TX
Red
Port disabled; may be due to Link Loss Forwarding (LLF)
Off No
link
Green Link
established
Green blinking
Receiving activity
Amber System
self-test
RX
Red
Receiving Remote Fault
Off Non-network
connection
Green Network
connection
NET
Amber System
self-test
Alarms
The 9161 can generate Traps and Major and Minor Alarms. For details about the Traps Log and
setting up notification, see Chapter 4.