Accessory Installation and Configuration
15-2
SkyView System Installation Guide - Revision S
RANGE 3, RANGE 4, RANGE 5
ENABLE: NO
(other parameters are ignored when ENABLE set to NO)
4. SETUP MENU > EMS SETUP > SCREEN LAYOUT EDITOR
SENSOR (button)
Select PHEAT (or custom name) CONTACT
ACCEPT (button)
Adjust size of the icon to your preference.
Adjust location of the icon to your preference.
SAVE (button)
5. Repeat step 5 for 20%, 50%, and 100% layouts as desired
6. Test:
When Pitot Heater Controller is OFF (or fault), EMS screen should display RED indicator
with text OFF (or your preferred text).
When Pitot Heater
Controller is ON, EMS screen should display GREEN indicator
with text ON
(or your preferred text)
.
Angle of Attack Audio Alert Volume
The volume of Angle of Attack audio alert can be adjusted independently of other audio alerts:
SETUP MENU > SYSTEM SETUP > AUDIO SETUP > AOA VOLUME: (0% TO 100%).