4-2
EMS-D10 Pilot’s User Guide
EMS Main Page
Available in full format
This page displays RPM, manifold pressure (MAP), oil temperature, oil
pressure, exhaust gas temperature (EGT), cylinder head temperature (CHT),
fuel level, fuel pressure and fuel flow. Up to four user-configurable info
items may be displayed at the right side of the screen. For information on
configuring the function of these info items, see the EMS Operation section
on page 7-1.
Up to six EGT/CHT channels may be displayed simultaneously. Green
horizontal bars depict exhaust gas temperatures with their respective values
to the right of the bars. In the combined EGT/CHT display, cylinder head
temperatures are denoted by the white vertical tic marks overlaying the
EGT bars with their respective numeric values to the left of the bars. In the
split EGT/CHT display (two cylinder engines only) CHTs are displayed
using their own set of green bars on a different scale than EGTs with their
respective numeric values displayed to the right of each bar.