Connecting static & pitot lines – Dynon Avionics EFIS-D10 Installation Guide User Manual
Page 14
EFIS-D10 Installation Manual
EFIS-D10 Installation Guide
Doc Num: 100006-000
Rev. C
9/11/2003 Page
14 of 24
Connecting Static & Pitot Lines
IMPORTANT NOTE:
The EFIS-D10 attitude calculation algorithm relies on data obtained
via the pitot and static lines. Therefore, to ensure proper unit operation, you must attach these
ports to the pitot/static system in your plane.
The AOA, pitot, and static ports on the back of the EFIS-D10 are equipped with 1/8” NPT
Female fittings. To attach your pitot and static lines to the back of the EFIS-D10, you must use
standard 1/8” NPT Male fittings at the end of each of the lines.
To install, simply T off your current static and pitot lines to bring a line to the EFIS-D10. The
ports on the back of the unit are labeled “A” (AOA), “P” (pitot), and “S” (static).