Technical data – Leica Geosystems SNLL121 User Manual

Page 27

Advertising
background image

© Leica Geosystems

SNLL121-2.1.0en

27

Location of laser

in the centre; turns with
instrument

Accuracy

max. diameter of the circular
movement of the laser point:
≤ 1.0 mm / 1.5 m

Diameter of laser spot

2.5 mm / 1.5 m

Level sensitivity

30" / 2 mm

Automatic switch-off

~ 4 min. after key is last pressed

Light source, red

laser diode 620 - 690 nm

Laser class

2

IEC60825-1;
EN60825-1

II

FDA 21 CFR Ch.I § 1040

Power supply

4 x 1.5V alkaline-Mn cells
Type AA (LR6, AM3, Mignon)

Protection / Sealing

IP54, in accordance with
IEC 60529 (splash-proof)

Dimensions

Height

153 mm

Diameter

102 mm

Weight

1080 g (2.4 lbs)

Temperature range
Operation

-20 °C (-4°F) to +50 °C (122°F)

Storage

-40 °C (-40°F) to +70 °C (158°F)

Technical Data