9

EN

Technical Data

* applies for 100 % target reflectivity (white painted wall),
low ambient light, 25 ºC
** applies for 10 to 500 % target reflectivity, high ambient
light, - 10 ºC to + 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confidence
level of 95%. The maximum tolerance may deteriorate to
0.1 mm/m between 10 m to 30 m and to 0.20 mm/m for
distances above 30 m
**** applies for 100 % target reflectivity, background illumi-
nation of approximately 30'000 lux

Message Codes

If the message Error does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message InFo appears with a number,
press the Clear button and observe the
following instructions:

General

Typical Measuring Tolerance* ± 1.0 mm / ~1/16" ***

Maximum Measuring
Tolerance**

± 2.0 mm / 0.08 in ***

Range at Leica target plate
GZM26

100 m / 328 ft

Typical Range*

0.05-80 m / 230 ft

Range at unfavourable
condition ****

50 m / 164 ft

Smallest unit displayed

0.1 mm / 1/32 in

Power Range Technology

yes

Laser class

2

Laser type

635 nm, < 1 mW

Ø laser point
at distances

6 /30 / 60 mm
10 / 50 / 100 m

Protection class

IP54 (dust- and splash
water protected)

Autom. laser switch off

after 90 s

Autom. power switch-off

after 180 s

Battery durability (2 x AAA)

up to 5000 measure-
ments

Dimension (H x D x W)

114 x 50 x 27 mm
4.49 x 1.97 x 1.06 in

Weight (with batteries)

126 g / 4.05 oz

Temperature range:
- Storage

- Operation

-25 to 70 °C
-13 to 158 °F
-10 to 50 °C
14 to 122 °F

Functions

Distance measuring

yes

Min/Max measuring

yes

Permanent measuring

yes

Stake-out

yes

Addition/Subtraction

yes

Area

yes

Volume

yes

Painter function (area with
partial measurem.)

yes

Pythagoras

2-point and 3-point

Memory

10 results

Beep

yes

Illuminated display

yes

Automatic multifunctional
endpiece

yes

No.

Cause

Correction

204

Calculation error

Perform measurement
again.

252

Temperature too high

Let device cool down.

253

Temperature too low

Warm device up.

255

Received signal too
weak, measuring time
too long

Change target surface
(e.g. white paper).

256

Received signal too high

Change target surface
(e.g. white paper).

257

Too much background
light

Shadow target area.

258

Measurement outside of
measuring range

Correct range.

260

Laser beam interrupted

Repeat measurement.