C. Wiring with the Connection Cable (WV-CA50)

The appearance and cord length is shown in the drawing.

The parts name of WV-CA50 is shown in the following.

No.

Parts name

1

18 wires cable

2

14P housing

3

12P housing

4

10P housing

5

8P housing

6

Contact

7

BNC connector

The wire gauge can be determined by the chart below.

• The system should be operated by 24V AC and the

power consumption should have less than 11W for the

camera.

Model

WV-7230D

Copper wire gauge AWG No.

Cable length

AWG size

Impedance

(fì/km)

11

13

#24

77.9

ft

30

65

m

10

15

#22

50.4

ft

50

100

m

15

30

#20

32.3

ft

80

155

m

20

45

#18

19.9

ft

130

250

m

40

70

• Cable assembly:

Strip back the cable jacket approx. 0.1 inch and
separate the individual conductors.

D. In case of using the accessory connectors

(MX5557P08 and MX5S57P10)

Select a multi-conductor cable which meets FR-1 rating

with 11 or 13 wires cables for WV-7230D.

12 wires cable is used to extend the cable lengt^

Connect the 11 or 13 wires cable to the following positions

of the accessory connectora

CN Pin No.

WV-7230D

Usage of Terminal

Power Source

CN1-1

LEFT

24 V AC

CN1-2

RIGHT

CN1-3

UP

CN1-4

Down

CN2-1

24V AC Camera

CN2-5{6)(7)

AC Common

CN1-7

DC COMMON

24V AC Common

CN1-8

Iris Control

±6V DC Common

CN1-9

Focus Control

±6V DC

CN1-10

Zoom Control

CN2-8

Camera Ground

• If 13 wires cable are available for WV-7230D, connect

the remainded 2 wires to the ( ) positioa

1

1

10

9 £

П 7

6

5

4 ;

П 2

1

8

7 6

5

4 3

2

1

CN1

CNZ

The accessory connectors view from wiring side.

Contact

Up >

^^3

Approx.

0.1 inch

Wire

2

^ Insert

Insert the wire until A position
and clamp the contacts.

Preparate the individual cortductors for clamping.
If clamping, use MOLEX brand tool part number
57027-5000 (for UL-Style Cable UL1015 or
57026-5000 (for UL-Style cable UL1007).

After clamping the contacts, push them into the proper

holes in the connector housing until they snap in place.

Up

Î

Wire

Contact

CAUTIONS:

Shrinking the cable-entry seal is a one-time procedure.
DO NOT shrink the cable-entry seal until it has been

ascertained that the unit is functioning.
CONNECT THIS TO 24V AC CLASS 2 POWER SUPPLY
ONLY.

Caution:

To prevent fire or shock hazard,

the UL listed wire VW-1, style 1007
should be used for the cable for 24V