CH Tech Active Module Carrier VX402C-64 User Manual

Vxibus compliance, Applications, Ordering information

Advertising
background image

Rev. A

C&H Technologies, Inc.

445 Round Rock West Drive

Round Rock, TX 78681-5012

(512) 733-2621

FAX (512) 733-2629

www.chtech.com

Mechanical:
• Mates with VXI, VME, and VME64

rear connectors

• VXI shielding provided
• Occupies one slot in a VXIbus C-

size mainframe

• Slot in front panel allows

extension of VME P2 signals to
front panel (cable not included)

VXI Power Consumption:

+5V

300 mA (max)*

-5.2V

100 mA (max)

-2V

10 mA (max)

±12V

0

±24V

0*

* Does not include power required

by installed module or +3.3V
power converter

+3.3V/+5V VME64 Supply:
• -0001 version provides up to 34W

for the combination of +3.3V and
+5V power

• -0002 version provides up to 34W

of +5V power (no +3.3V power
supplied)

• -0003 & -0004 versions provide

up to 34W of +5V power and up to
21W of +3.3V power

VXIbus Compliance

Complies with VXIbus Spec.
Rev. 1.4 for single-slot C-size
modules and with the VMEbus
Spec. ANSI/IEEE STD 1014-1987,
IEC 821 and IEC 822.

Addressing:

A32/A24/A16

Data Transfers:

D32/D16 Slave

Interrupts:

Supported

Triggers:

Supported

Applications

• VXI A or B-size to VXI C-size
• VME module to VXI chassis
• +3.3V supply to VME64 module

Ordering Information

Part Number: 11028500-xxxx

-0001 3.3V supplied from VXI +5V
-0002 without 3.3V supply
-0003 3.3V supplied from VXI -24V
-0004 3.3V supplied from VXI +24V

Additional Information

User Manuals for C&H carriers and
this module can be found on our
website at www.chtech.com.

Specifications:

Electrical:

• Active logic allows compliance

with VME/VXIbus driving and
loading specifications

• Provides VME64 +3.3V power

and grounds (except -0002)

• All VXI power supplies are fused

• Provides direct access to the front

panel I/O connections

• Provides buffered data, address,

interrupt, and trigger lines (ECL
and TTL)

• Includes

direct

SUMBUS

connections and a prototyping
area

• Pass-through connectors allow

the VME P2 connector to be
connected or isolated from the
VXI P2 backplane

Temperature:

Operating:

0°C to 50°C

Storage:

-40°C to 70°C

VX402C-64
Active Module
Carrier

The VX402C-64 allows a 3U or 6U
VME, VXI (A or B), or VME64
module to be used in a C-size VXI
mainframe chassis. The carrier
provides an actively buffered
electrical interface for the standard
bus signals. The carrier does not
support the full VME64 extension
bus; however, some versions
provide +3.3V power to the P1
Row D VME64 connector. The
carrier and its enclosure have been
designed so that the front panel of
the VME module sits flush with the
front panels of other C-size
modules.

(VXI top shield included,
but not shown in picture)

Advertising