Electrical work noise considerations, Transferring, Removal of the grille – Panasonic CW-1273FR User Manual

Page 11: Drain water

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Electrical work

Noise considerations

Always use at the rated voltage.

Some installation locations may require installation of
a shortcircuit breaker.
A 10 Ampere time delay fuse or circuit breaker is
required.
Nominal cross sectional area of power supply wire
must be 3 core x 1.0 mm^ or above.
The power supply must be from an independent circuit.
All electrical installation must be made in accordance
with local wiring and safety regulations wherever
applicable.

Please consult your dealer concerning installation
requirements.

Transferring

When repositioning the air conditioner due to

renovations, or when transferring to a different
location, the removal and reinstallation of the unit
requires an additional service charge. Please consult

your dealer before moving.

Removal of the grille

1) REMOVE AIR FILTER

2) REMOVE FRONT GRILLE

• Loosen the screws at the right, left and centre

of the grille.

• Press the side of the cabinet firmly and at the same

time pull the corner of the grille forward to

unhook the tabs.

• Slide the grille upward to free the two tabs at the

top of the grille from slots at the top of the cabinet.

CABINET

• Select an installation location that can support the

weight of the air conditioner and one that will not cause

increased operating noise and vibration.

• Ensure that airflow and noise from the rear side

of the unit (outdoors) when installed do not cause
inconvenience to neighbouring residents.

• Obstacles placed in front of the air outlet on the

rear side of the unit (outdoors), or covers placed

over it, cause excessive noise and a deterioration in
performance.

Drain water

To get the maximum cooling efficiency this air
conditioner is designed to splash the condensate
on the condenser coil.
This method is called “Slinger-Up System”.

If the splashing sound annoys you, you can provide
an outside drain by using the following procedure

which may, however cause a small loss of

performance.

1. Slide out the chassis from the cabinet.

2. Remove the rubber plug from the body base plate.
3. Install the drain pan prepared in the accessory kit to

the corner of the cabinet with 2 screws.

4. Connect the drain hose to the outlet on the drain pan

bottom.

5. Slide the chassis into its original place in the cabinet.

Note: Drain hose or tubing can be purchased locally to
satisfy your particular needs.

(CW-903FR, CW-1203FR)

(CW-973FR, CW-1273FR)