Bench / Static Adjustments

Any adjustment can be made without operating the machine. This process is known as “static” or “on the
bench” calibration. Use the following steps -

Provide power to the Superflex 4 Controller. Connect the Optimizer.

Select a “function” (channel) by pressing the Function Select key one or more times, until the
desired channel (1 through 4) is displayed.

Select a direction (A or B) by pressing the DIR A/B key.

Select a controller adjustment by pressing one of Threshold, Maxout, Low Range, Ramp Up or
Ramp Down keys.

Use the Plus and Minus keys to make the adjustment.

Press RUN to save the changes before powering down or disconnecting the Optimizer.

Factory Default Values (Appendix 3)

All defaults (preset values) as well as upper and lower limits to each adjustment range may be specified by
the customer. These setting are installed by OEM Controls when your Superflex 4 Controller is
manufactured. After making adjustments with the Optimizer, it may be desirable to return to these default
values. This task is easily accomplished with the Optimizer.


Apply power to the Superflex 4 Controller and connect the Optimizer.

Press the Menu key. Then press the Enter key several times, until the Optimizer displays “Restore
Defaults?”.

Press the Plus key to restore the default values. The Optimizer displays “BUSY” while the
original values are copied. This may take several seconds, depending on how many values need to
be restored. Then the Optimizer will momentarily display “DONE” and return to the default run
screen. Be sure to wait for this to happen before disconnecting the Optimizer or turning off power
to the Superflex 4 Controller.