General oPeration

The ThermElect Hydronic heating system stores de-

mand off-peak electricity in the form of heat.
Operation of the heating system is automatic. During

hours when energy costs are lower the system converts

electricity to heat which is then stored in its ceramic

brick core. The amount of heat stored in the brick core

of the system varies in relation to outdoor temperature,

utility peak conditions, and/or the heating require-

ments.
A heat call from the thermostat or main system control

energizes the primary water loop pump. The vari-

able speed core blower automatically adjusts its speed

to achieve the desired outlet water temperature. The

heated water is then pumped to the area (zone) from

which the heat call originated.
The versatility of this system allows it to fit many ap-

plications. The system is designed for use as either a

sole heating source (“stand alone” furnace) for make

up air heating or as a supplement to another ducted

heating system such as a heat pump.

SySteM uSe DurinG

conStruction PHaSe

Like most heating equipment manufacturers, Stef-

fes strongly recommends that “Construction Heating

Units” be used instead of the permanent heating system

during the construction phase. Use of the permanent heating system during this phase may contaminate the duct

system and/or internal areas of the heating system. This may cause poor indoor air quality issues and/or improper

system operation or equipment damage.

SySteM Start-uP

On start-up of the ThermElect Hydronic system, odors relating to first time operation of the heating components

may be experienced. Allow the system to charge to its maximum brick core charge level, on start-up, to expel

these odors. If the system has not been used for an extended period of time, dust may accumulate in the system.

Upon restart, there may also be an odor as these dust particles are expelled.
During operation, the system may produce minor expansion noises. These noises are the result of the internal com-

ponents reacting to the temperature changes.

turninG SySteM "off" anD "on"

The system is fully automatic and does not need to be manually disabled. Talk to your installer or energy manage-

ment person for additional information.

T

herm

e

lecT

h

ydronic

o

peraTion

1.01

operation

1

o

per

ation

SUPPLY

WATER

WATER

RETURN

VARIABLE SPEED

CORE BLOWER

MOTOR ASSEMBLY

225° AUTO

RESET LIMIT

250° MANUAL

RESET LIMIT

AIR TO WATER

HEAT EXCHANGER

HEAT

STORAGE

BRICK

HEATING

ELEMENT