SPECIALTY APPLICATION WIRING DIAGRAM

(six pole configuration utilizing power line carrier signal and an

auxiliary control device)

This Device MUST be Grounded.

Grounding and Bonding is not shown in this Diagram.

Optional Auxiliary Control

In This Example, Circuits 4,5,&6

are Controlled by PLC Signal Only

Auxiliary Control.

CIRCUIT 6

CONTROLLED LOAD

CIRCUIT 5

CONTROLLED LOAD

CONTROLLED LOAD

CIRCUIT 3

CONTROLLED LOAD

CIRCUIT 2

CONTROLLED LOAD

CIRCUIT 4

CIRCUIT 1

CONTROLLED LOAD

and by an Optional

Controlled by PLC Signal

Circuits 1, 2, and 3 are

In This Example,

C

R

6

C

R

4

C

O

M

C

R

1

C

R

2

C

R

3

C

R

5

L2

L2

T1

CIRCUIT 5 CIRCUIT 6

T1

T1

L2

L2

CIRCUIT 2

T1

CIRCUIT 3

T1

L1

CIRCUIT 1

T1

L2

12

0

24

0

L1

C

TS

206

-8

3

O

N

2

1

6

5

78

4

95

04

10

9

CIRCUIT 4

L2

(i.e. room thermostat)

Lo

w

V

ol

ta

ge

T

er

m

in

al

S

tri

p

IMPORTANT

w

The equipment described herein is intended for installation by a

qualified technician in accordance with applicable local, state, and

national codes and requirements.

w

This manual should be retained by the owner upon completion of the

installation and made available to service personnel as required.

w

Disclaimer:

ΠConditions may occur which cause the power line carrier

transmitter and receivers to have difficulties communicating;

therefore, not operating properly. In no event shall Steffes

Corporation be liable for any indirect, special, or consequential

damages or lost profits.

ΠIn compiling this manual, Steffes Corporation has used its best

judgement based upon information available, but disclaims any

responsibility or liability for any errors or miscalculations

contained herein, or any revisions hereof, or which result, in

whole or in part, from the use of this manual or any revisions

hereof.

WARNING

HAZARDOUS VOLTAGE: Risk of electric shock, injury, or

death. System may be connected to more than one branch

circuit. Disconnect power to all circuits before servicing.

Equipment must be installed and serviced by a qualified

technician.

F

OR

C

USTOMER

U

SE

Please record the serial number of the mini receiver below. This information

is located inside the mini receiver enclosure. Retain this information for

future reference.
Serial No.________________________________________________