SE FLOWSTAR PUMP STATION - 221337

8 Technical data and pressure drop curve

Technical data

SE Flowstar Pump Station

Dimensions

Height

14.9 in. / 379 mm

Width

8.94 in. / 227 mm

Depth

5.9 in. / 150 mm

Upper & lower connections ¾˝ Male NPT or ¾˝ Female BSP
Exp. tank connection

¾˝ Male BSP

PRV connection

¾˝Female BSP

Temperature & Pressure

Max. pressure

145 PSI / 10 bar

Max. temp.

248F / 120C

Max. short term temp.

320F / 160C for < 15 min.

Max. propylene glycol %

50%

Equipment

Pressure relief valve

87 psi / 6 bar

Pressure gauge

0-87 psi / 0-6 bar

Check valve

7.9 in. head / 200 mmWC

Flowmeter

0.1-4 gpm

Material

Valves & fi ttings

Brass

Gaskets

EPDM

Check valves

Brass

Insulation

EPP, λ=0.043 W/(m•K)

Dimensions

Below is a diagram of the spare parts that can be ordered
from Stiebel Eltron. If you need to order a replacement part,
please contact Stiebel Eltron and use the part numbers
below as a reference.