Replace GCU cover and mount
near gate operator control box.

Remove bottom panel of GCU.
Connect Terminal 10 on GCU
to Common on gate operator
(shown below).
Connect Terminal 9 to Cycle on
gate operator (shown below).

1

3

2

4

5

6

7

8

9 10 11

DC

AC

+

-

COM

N/C

EXIT

SAFETY

EDGE

COMMON

OPEN

GRN

BLK

RED

RECR

N/O

GATE OPERATOR

GCU

Installation

Wiring to Gate Operator

2

Operation

To open a gate enter any valid PIN Number on
GAPLM. For multiple GCU’s, enter the PIN Number
followed by the GCU Identity (1-4).
For a remote control transmitter, press the
corresponding button for 3 seconds (within 75' of
GAPLM).
On an Intercom, press the Remote button while
talking to a visitor. At other times, hold the intercom’s
Remote button for 10 seconds, to activate the Primary
GCU.
NOTE: If the gate operator is not set to automatically
close the gate, any of the above methods can be
repeated to close the gate.

Open/Close Gate

1

3

2

4

5

6

7

8

9

10

11

DC

+

-

N/O

COM

N/C

AC

Gate Terminals

Optional Power Inputs:
• Terminals 1 and 2: Optional 10-24 Vac power input.
• Terminals 1 and 3: Optional 9-24 Vdc power input.
Ensure that the gate’s DC power supply “Ground” is
wired to terminal 3.
Relay Outputs:
• Terminal 9: Relay Normally Open contact.
• Terminal 10: Relay Common.
• Terminal 11: Relay Normally Closed contact.
Relay connections typically wire to Open Gate input
on gate operator.
NOTE: Output switching capacity is low voltage (24V
max, ac or dc).

Unused Contacts:
• Terminals 4-8: Not used.

To prevent possible SERIOUS INJURY or DEATH from
electrocution, outputs are suitable ONLY for controlling low
voltage devices, 24V max, ac or dc.