CYV15G0404RB

Document #: 38-02102 Rev. *C

Page 22 of 27

CYV15G0404RB Device RESET Characteristics Over the Operating Range

t

RST

Device RESET Pulse Width

30

ns

CYV15G0404RB Reclocker Serial Output Characteristics Over the Operating Range

Parameter

Description

Condition

Min.

Max.

Unit

t

B

Bit Time

5128

660

ps

t

RISE

[14]

CML Output Rise Time 20

−80% (CML Test Load)

SPDSELx = HIGH

50

270

ps

SPDSELx = MID

100

500

ps

SPDSELx =LOW

180

1000

ps

t

FALL

[14]

CML Output Fall Time 80

−20% (CML Test Load)

SPDSELx = HIGH

50

270

ps

SPDSELx = MID

100

500

ps

SPDSELx =LOW

180

1000

ps

CYV15G0404RB AC Electrical Characteristics

(continued)

Parameter

Description

Min

Max

Unit

PLL Characteristics

Parameter

Description

Condition

Min

Typ

Max

Unit

CYV15G0404RB Reclocker Output PLL Characteristics

t

JRGENSD

[14, 22]

Reclocker Jitter Generation - SD Data Rate

TRGCLKx = 27 MHz

133

ps

t

JRGENHD

[14, 22]

Reclocker Jitter Generation - HD Data Rate

TRGCLKx = 148.5 MHz

107

ps

CYV15G0404RB Receive PLL Characteristics Over the Operating Range

t

RXLOCK

Receive PLL Lock to Input Data Stream (cold start)

376k

UI

Receive PLL Lock to Input Data Stream

376k

UI

t

RXUNLOCK

Receive PLL Unlock Rate

46

UI

Note

22. Receiver input stream is BIST data from the transmit channel. This data is reclocked and output to a wide bandwidth digital sampling oscilloscope. The

measurement was recorded after 10,000 histogram hits, time referenced to REFCLKx± of the transmit channel.

Capacitance

[14]

Parameter

Description

Test Conditions

Max

Unit

C

INTTL

TTL Input Capacitance

T

A

= 25°C, f

0

= 1 MHz, V

CC

= 3.3V

7

pF

C

INPECL

PECL input Capacitance

T

A

= 25°C, f

0

= 1 MHz, V

CC

= 3.3V

4

pF

[+] Feedback