Byte 32

DP15

DP14

DP13

DP12

DP11

DP10

DP9

DP8

DP is the 16-bit integer number of data points in the spectrum scan. The value will

depend upon the frequency step size specified in Byte1. The next 4 data bytes will

be repeated DP times.

b7

b6

b5

b4

b3

b2

b1

b0

Byte 33

OFS7

OFS6

OFS5

OFS4

OFS3

OFS2

OFS1

OFS0

Byte 34

OFS15

OFS14

OFS13

OFS12

OFS11

OFS10

OFS9

OFS8

Byte 35

PEAK7

PEAK6

PEAK5

PEAK4

PEAK3

PEAK2

PEAK1

PEAK0

Byte 36

AVG7

AVG6

AVG5

AVG4

AVG3

AVG2

AVG1

AVG0

...

Repeat DP times to read all the spectrum data

OFS is the 16-bit integer Index value for this data point. The range of this index is

0 to (128 − Frequency Step Size). For example, with a step size of 1, the maximum

value of OFS is 127, but with a step size of 8, the maximum value is 120.

PEAK is an 8-bit integer representing the peak power detected at each frequency.

AVG is an 8-bit integer representing the average power detected at each

frequency.

Both the PEAK and AVG readings are a logarithmic scale, with a value of zero cor-

responding to -100 dBm and a value of 255 corresponding to -15 dBm:

Power in dBm = − (100 − ((Sample Value) / 3))

Please be aware that this scale is approximate. Linearity is poor above -20 dBm or

below -90 dBm.

XC1220

5 KB Receive FIFO

8 KB Transmit FIFO

Host

Microcontroller

SPI or

UART

Data Commands

The data commands are used to transfer data between the XC1220 and the host

microcontroller that is intended for RF transmission.