s

PeciFicAtioNs

GPIO Plugs

Plugs used with the GPIO terminal blocks have the following specifications.

Pitch

3.81 mm

Number of positions

8

Type of connection

Screw

Screw thread

M 2

Conductor cross section AWG/

kcmil

minimum 28

maximum 16

Plugs used with Pro64 products are compatible with Phoenix

Contact™, part number 1803633, or equivalent.

MIDI/GPIO Cable Lengths

To meet the EN55103‑2 (Electromagnetic Susceptibility/Immunity)

Specification, any cables connected to the MIDI and/or GPIO ports must not

exceed three meters in length. Use of cables longer than three meters will

not guarantee equipment conformance to EN55103‑2.

Factory Default Settings

When a Pro64 module is reset to the factory default settings using Function

16, the following settings are restored:

A‑Net Slot is set to 1.

•

Auto Mode is selected.

•
• Sample Rate is set to 48kHz.

All audio channels are muted and deactivated for

•

Auto,

Manual, and Managed Modes.
All stereo links are deactivated for Auto, Manual, and

•

Managed Modes.
Managed Mode is deactivated.

•
• Edit Lock is set to off.
• Password protect is off.

The system

•

password value for the module being reset is

“1‑1‑1‑1.”
All Virtual Data Cables are deactivated.

•