Ontrol, Aster – Aviom 6416Y2 User Manual

Page 23

Advertising
background image

13

c

ontrol

m

aster

c

oNtrol

m

aster

In every Pro64 network, one device will always be designated as the Control Master, the device that manages all

A‑Net resources for the network. The Control Master can be any I/O module in the network, and can be assigned

or changed by the user as needed. Only one device can be assigned as Control Master in a Pro64 network at a

time; an A‑Net Pro64 network cannot function without a Control Master.

The functions of the Control Master include:

System resource and information management

•

Management of

•

active channels (Slots)

System‑level command and control functions

•

Keeping track of all Pro64 devices in the network (by type and quantity)

•

Control of the current system‑wide

•

sample rate

•

Clock Master (analog modules only)
System lock via

•

password on/off for supported devices

Management of

•

Virtual Data Cable (VDC) resources

Management of

•

stereo link status

Requests to enter

•

Managed Mode for control with Pro64 Network Manager software

Communication with

•

Pro64 Network Manager software when configuring and managing a

network using a PC

The Control Master status is identified with a red LED on the front panel of the device currently assigned as the

Control Master. Depending on the type of device (rack‑mounted I/O module, AllFrame, or digital console interface

card), the method used for designating Control Master status may be different.

The Control Master LED is labeled CTL on the 6416Y2 card.

RS–232/422

STEREO LINK

6416

Y2

B

A

ON

CTL

CLK

AUTO

ERR

1 2 3 4 5 6 7 8 9 10 11 12

The Control Master LED (CTL) on the 6416Y2 card

Advertising