Trouble shooting, Front view, Side view – California Faucets In Wall Diverter with Swivel Ports User Manual
Page 2
![background image](/manuals/656148/2/background.png)
Pg 2
WDV-R_ii_130920
-Install trim, (base ring if applicable), escutcheon and handle and tighten set screws with allen key
provided.
TROUBLE SHOOTING
1. Leak at body nut, and or between
broach and sleeve.
2. While using one outlet, there is water
leaking from the other outlet.
Replace cartridge. The stem O-Ring on cartridge is defective.
To replace, remove all thread, broach, body nut and cartridge.
Fit new O-Ring and apply silicone grease. Reinstall cartridge
as described in the instruction sheet.
The stem O-ring is damaged.To replace the o-ring,
remove trim, body nut, then the stem.
"A"
DIMENSION
"A" Dimension is
from finished wall
to tip of stem broach
(Marked "IN")
(Marked "1, 2 & 3")
Inlet:
1/2" NPT
Outlets:
1/2" NPT
Fig. 4
IN
1
2
Front View
Stem
Broach
Fig. 5
3
1
"A" Dimension
9/16"
All Thread
Finished
Wall
Side View
IN
NOTE: When fitting handle it
may be necessary to shorten
broach and/or all thread to
eliminate gaps between
handle and escutcheon.
2-Way Stop Ring
3-Way Stop Ring
Body Nut
Cartridge
Detent Disk
Valve Body
Fig. 3
IN
3
1
(O-Rings)
1
2
3
8
6
4
9
Broach O-Ring
7
2
5
6
3
4
1
5
Broach
8
Fig. 5
7
All Thread
9
Pressure:
Maximum = 125 P.S.I. - 8.6 Bar
Hot water supply temperature = Maximum 185 °F/ 85 °C
C.S.A., A.S.S.E. & I.A.P.M.O. U.S. & CA. & WDR-NS-R: CA GREEN
3
NOTE:
Cap off any unused outlets to
avoid potential water leakage
behind the wall.
3"
3"
5-1/4"
4-3/4"
6-1/8"
Ø 1-1/2" Opening
HANDLE
SERIES No.
"A"
33
2-3/8"
34
2-3/8"
35
2-3/8"
36
2-3/8"
38
2-5/8"
40
2-5/8"
42
2-5/8"
44
2-7/16"
46
2-1/2"
47
2-1/2"
48
2-5/16"
50
2-1/4"
51
2-1/2"
53
2-1/4"
55
2-5/8"
57
2"
59
2-5/8"
60
2-1/4"
62
1-7/16"
63
3"
64
2-5/8"
65
2-1/8"
66
2-1/8"
67
2-1/4"
68
2-3/8"
69
2-3/8"
70
1-3/8"
71
1"
72
1"
73
1"