California Faucets Styletherm 1/ Thermostatic Rough Valve with Dual Outlet Integral Diverter User Manual

Page 2

Advertising
background image

1

INSTALLING VALVE TO FRAME

• Determine the desired location for the valve,

construct suitable stud, and support framing

• Attach VALVE (1) to CROSS SUPPORT (2) by

using SCREWS (3) (not supplied) as shown

• The valve should be level in HORIZONTAL,

VERTICAL and PARALLEL to wall

• Placement of VALVE (1) and CROSS SUPPORT (2)

within the wall shall be determined by the

MIN/MAX Limits shown on MUDGUARD (4)

• For complete detailed VALVE (1) dimensions see

.

5

. ROUGH-IN DIMENSIONS

2

WATER

CONNECTIONS

• Remove and discard THREAD PROTECTORS (5)

• Pre-assemble FITTINGS (6) prior to attaching to

VALVE (1)

• Apply thread sealant to all FITTING (6) threads and

attach to VALVE (1)

• Attach “COLD” INLET to COLD SUPPLY and

“HOT” INLET to HOT SUPPLY. All soldering of
FITTINGS (6) shall be performed a

minimum of 4” away from VALVE (1)

• Perform all other required connections to output

device(s) (i.e. showerhead, handshower, etc…)

• Turn on water supply and check for leaks

IMPORTANT: Flush supply lines prior to installation to prevent
damage and malfunction of thermostatic cartridge.

IMPORTANT: Cold water supply must be connected to inlet
marked “COLD” and hot water supply must be connected to inlet
marked “HOT”.

CAUTION: This valve contains plastic and rubber components. Do
not sweat or braze directly to the valve body. Do not apply excessive
heat to the valve body when you make solder connections. Do not

apply flux or acids directly to the valve, as damage to the seals, plastic
components, and trim finish may result.

Finished

Wall

HOT

SUPPLY

COLD

SUPPLY

CAUTION: Inlet and outlet threaded joint connections should be
made with plumbers PTFE tape or liquid sealant. Oil-based, non-setting

compounds should not be used.

WARNING: Forcibly rotating thermostatic cartridge stem prior to
installing handle trim, will damage cartridge and void warranty.

TH51D2-R_ii_130102.doc

Pg

2

Advertising