2.2 Operating Elements

1

2

3

4

5

6

7

9

8

10

0

1. Measuring Wheel

0

6. Handle

0

2. ON / RESET Switch

0

7. Filament Guide Ring (LMC-S, LMI-S only)

0

3. Display

0

8. Connector for Magnetic Switch

0

4. Batteries (2), 1.5V AAA

0

9. Preset Switch x 1

0

5. End Cover

10. Preset Switch x 10

2.3 Inserting The Batteries

Before first use of the instrument, the batteries four need to be inserted. If the

display switches off while the instrument is running and the measuring wheel is

rotating, the batteries 4 need to be replaced.
To insert the batteries:
1. Remove the end cover (5).
2. Insert the batteries into the battery compartment inside the handle.

Please ensure proper polarity.

3. Screw the end cover back into the handle.

NOTE: If the instrument will not be used for an extended period of time, the

batteries should be removed.

9

4.3 Taking Measurements with Auto Start / Stop Signal

1. Insert the material to be measured in the groove of the filament guide ring 7

on the rear side of the instrument. The filament guide ring can be turned

by 360°.

2. Adjust the electronic yarn consumption meter in such a way that the angle of

material contact with the measuring wheel is 120° minimum (see fig. 3.4d)

to eliminate material slip.

3. Press the ON / RESET switch (see diagram on page 4).
4. As soon as the yarn consumption meter receives the first switching pulse

from the magnetic switch, it starts counting the selected number of

revolutions. Counting starts from 0.
The yarn consumption is also evaluated and shown on the display after the

first switching pulse of the magnetic switch.

5. When the number of revolutions set with the preselect switches and

has been reached, the instrument stops measuring.
The display shows the measured yarn consumption.
If a new yarn consumption measurement is necessary, repeat the measuring

process from step 3 to ensure that the instrument has been reset.

NOTE: The electronic yarn consumption meter powers off automatically when

the measuring wheel on the rear of the instrument has not been moving for about

two minutes. The measured values are deleted.