COP-USA AS20RS485 User Manual

Indoor / outdoor pan/tilt system

Advertising
background image

Indoor / Outdoor Pan/Tilt System

I

.Features:

z Compact and attractive appearance, Indoor / Outdoor design

;

z Motor running stably

;

z Flame-retarded ABS material

;

z Adjustable horizontal limit switcher, the unit capable of operation with load to 6Kg

;

z RS485 data communication

;

z With internal decoder, Multi-protocol, baud rate for selectable

;

z Pan speed: 5°/sec

; Tilt speed: 5°/sec;

z With line scanning function

;

II

.Description of the Dip-switcher setting:

1.Dip-switcher

ON DI P

1 2 3 4 5 6

ON DI P

1 2 3 4 5 6 7 8 9 10

SW2

SW1

6-Dip switcher: 1 – 4 for Protocol, 5 – 6 for Baud rate

;

10-Dip switcher(frontal 9-DIP) is for the address setup:1

~511, count it as the binary system.

2

.The setting of the protocol and the default baud rate:

Protocols

Selection of Protocols

Normal Baud Rate

DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6

SAMSUNG

ON

OFF

OFF

OFF

OFF

ON

B01

ON

OFF

OFF

OFF

OFF

ON

PELCO-D

ON

ON

OFF

OFF

OFF

OFF

PELCO-P/4800

OFF

OFF

ON

OFF

ON

OFF

PELCO-P/9600

OFF

ON

Longcomity

OFF

ON

ON

OFF

OFF

ON

HUNDA600

ON

ON

ON

OFF

OFF

ON

LILIN

OFF

OFF

OFF

ON

OFF

ON

Advertising