Cub Cadet ISeries User Manual

Page 145

Advertising
background image

ELECTRICAL SYSTEM

139

11.

Testing switches:

•

Refer to the “COMPONENTS” section of this
chapter that describes the function of the individ-
ual switches to be tested.

•

Switches can be tested “hot” by looking for volt-
age at the appropriate posts. This is not defini-
tive, since the source of the voltage is not always
confirmed. Checking for voltage does not work
on switches that work by providing a ground
path to the magneto primary windings or a solid
state control device.

•

The most valid way to test switches is a conti-
nuity test.

11a. Understand the internal functions of the

switch. Key switches and PTO switches
can be fairly complex.

11b. Isolate the switch from the rest of the cir-

cuit.

11c. Test each pair of terminals for continuity in

all modes of switch operation: at-rest, and
actuated.

11d. Many switches on Cub Cadet equipment

are typed by their at-rest state: Normally
Open, Normally Closed, Common.

•

Normally Open (N.O.) contacts do not complete
a circuit when the switch is at-rest (plunger
extended). They close to complete a path
through the switch when the plunger is
depressed.

•

Normally Closed (N.C.) contacts complete a cir-
cuit when the switch is at-rest (plunger
extended). They open to break the path through
the switch when the plunger is depressed.

•

Some Cub cadet switches contain more than
one pair of contacts. The same switch housing
can contain normally open and normally closed
switch elements.

•

When testing a switch that contains more than
one set of contacts (elements), the male spade
terminals associated with Normally Closed con-
tacts will be stamped “N.C.”

•

The male spade terminals that are associated
with each-other face each-other broad-surface
to broad surface. See Figure 7.45.

12.

Diodes

What is a diode? A diode acts like a one way

valve, allowing current to flow in only one direction.
See Figure 7.46.

•

Which way does this electrical check-valve
work? There will be a band on one end of the
diode. The band indicates the negative side of
the diode

•

Most DMMs have the ability to test a diode.

Figure 7.45

Normally Closed
switch element:

Spades marked: “NC”

Normally Open
switch element:

Spades blank

Figure 7.46

Silver band

(-)

(+)

electrons flow from the negative to the positive.

Advertising