4 split (4) – Doepfer LMK4+ Midi Master Keyboard (new version with USB) User Manual
Page 12

LMK4+ User's Guide Page 12
YYYYYYY is one of the following 4 choices that can be adjusted together with the MIDI-master-channel XX via the
rotary encoder:
POUT1&2
external Preset call-up active / Outputs 1&2
POUT1&0
external Preset call-up active / Output 1
POUT0&2
external Preset call-up active / Output 2
OUT1&2
external Preset call-up turned off / Output 1&2
In case of POUT... (first 3 choices) the Preset call-up via incoming MIDI Program-Change messages on the
Master-channel is active. If a suitable MIDI Program-Change message appears at the MIDI input of the LMK4+ the
new preset is chosen. The incoming Program-number is identical to the Preset-number.
In case of OUT1&2 the Preset call-up option is turned off. The presets cannot be switched by incoming Program-
change messages.
The combination of numbers 1&2, 1&0, 0&2 displays on which of the MIDI outputs the messages of menu 2 (i.e.
Program-Change and Bank-Select messages in direct mode) are sent. If these messages should appear on both
MIDI outputs 1&2 is chosen. If only one output is desired 1&0 (only output 1) or 0&2 (only output 2) is selected.
If you operate the rotary encoder at first the MIDI channel 1....16 within one mode is passed through. Exceeding
channel 16 the next mode is displayed. Falling short of 1 the previous mode is chosen.
The Master-channel/Preset call-up/output option is one of the parameters of PRESET and is stored in the preset-
memory.
The bottom row of buttons is not used in this menu (i.e. the NUMBER-buttons).
2.3.4 Split (4)
This menu is selected by pressing the fourth menu-switch from left. It is used to define the split-parameters in the 8
keyboard zones. The following message appears in the display:
ZONE : 00X
L/U/C/T/D/A/P/V
The 8 BANK-buttons are used to select one of the 8 keyboard zones. The number of the zone (00X) selected will
appear in the top line of the display. The lower line of the display is a symbolic representation of the functions
which can be activated in this menu via the NUMBER-buttons. The 8 characters correspond to the 8 buttons. A
function is activated by pressing the appropriate switch. The abbreviations are as follows:
LLower key of the keyboard zone
U
Upper key of the keyboard zone
C
(MIDI-) Channel, source (int./ext.) and MIDI-output of the keyboard zone
TTransposition of the keyboard zone
D
Dynamic table (= Velocity response table) for the keyboard zone
A
Aftertouch table for the keyboard zone
PProgram/Bank-number for the keyboard zone
VVolume for the keyboard zone
Once a function has been selected via the corresponding NUMBER-button it is confirmed on the
display. The value currently set will be shown to the right of the function name.
In order to change one of the parameters selected with the NUMBER-buttons, the rotary encoder (data-entry dial)
has to be used. For example, to adjust the Volume for of a keyboard zone one has to select the zone with one of
the BANK-buttons, followed by selection of the VOLUME-function through pressing the right NUMBER-button. The
desired value is then set with the rotary encoder and will be shown on the bottom line of the display.
The UPPER and LOWER key parameters can also be adjusted via the keyboard. After pressing a
key (=lowest key) on the keyboard while in the LOWER KEY-submenu, the program will immediately
jump to the UPPER KEY-submenu. After another keyboard-key is pressed (=highest key) the
program jumps to the CHANNEL-submenu.