Cleveland Range P-KDL-200-CC User Manual

Page 2

Advertising
background image

SECT.

XIV

PAGE

14

0907

Litho in USA

Cleveland Range reserves right of design improvement or modification, as warranted.

OPTIONAL

CONNECTIONS

LOCATED ON SIDE

QUICK DISCONNECT

FOR FOOD PUMP

(LOCATION VARIES)

IF KETTLE IS MORE THAN 3'

FROM THE CONTROL PANEL

THEN THE PRODUCT VALVE

SWITCH WILL BE KETTLE MNTD.

(LOCATION VARIES)

4"

OPTIONAL HOT

FILL WATER ONLY

69"

69"

24"

40"

D

E

C

A

B

F

OVER FLOW

PLAN VIEW

DEPTH 18 3/4"

CONTROL PANEL

DUAL CONTROL PANEL

P-DR-CC

P-SR-CC

SINGLE CONTROL PANEL

SIDE VIEW

OPERATIONAL

FRONT

A

D

CR

NOTE:

12 1/2"

DIMENSIONS

MODEL

A

B

C

D

E

F

ELECTRICAL PER KETTLE-

120V/1PH/60Hz

P-KDL-60-CC

32"

52"

45 1/2"

8"

24"

56"

10 AMPS

P-KDL-100-CC

39"

59"

49 1/2"

9"

28"

60"

10 AMPS

P-KDL-150-CC

45"

63"

55 1/2"

9"

30"

66"

10 AMPS

P-KDL-200-CC

49"

67"

57 1/2"

9"

32"

68"

10 AMPS

UTILITY CONNECTIONS

CHILLED

CHILLED

COLD

COLD

WATER

WATER

POTABLE

HOT

CONDENSATE

AIR

INJECTOR

MODEL

INLET

RETURN

WATER

WATER

RETURN

DRAIN

INLET

STEAM

WATER

P-KDL-60-CC

3/4"

3/4"

3/4"

3/4"

1/2"

3/4"

1/2"

3/4"

3/4"

15 GPM

15 GPM

15 GPM

1 CFM

320 lbs/hr

15 GPM

P-KDL-100-CC

1"

1"

3/4"

3/4"

3/4"

1"

1/2"

1"

3/4"

20 GPM

20 GPM

20 GPM

1 CFM

525 lbs/hr

20 GPM

P-KDL-150-CC

1 1/4"

1 1/4"

3/4"

3/4"

1"

1 1/4"

1/2"

1 1/4"

3/4"

20 GPM

20 GPM

20 GPM

1 CFM

780 lbs/hr

20 GPM

P-KDL-200-CC

1 1/4"

1 1/4"

3/4"

3/4"

1"

1 1/4"

1/2"

1 1/4"

3/4"

25 GPM

20 GPM

20 GPM

1 CFM

1050 lbs/hr

20 GPM

** HOT FILL WATER IS OPTIONAL

65 PSI STEAM OPERATING PRESSURE IS RECOMMENDED

**

ELECTRICAL POWER

TO AND FROM

CONTROL PANEL
• CONTRACTOR

MUST CUT ENTRY
HOLE

• TOP OR BOTTOM

POWER ENTRY
RECOMMENDED

• MUST USE PROPER

CONNECTIONS TO
MAINTAIN U.L.
LISTING

(NOT TO SCALE)

MINIMUM CLEARANCE

FOR KETTLES

FRONT

36"

SIDE

12"

REAR

12"

NOTES: The pressure drop is 12 to 15 PSI for steam and chilled water passing through the kettle.

Air must be dry, clean and free of oil.

Advertising
This manual is related to the following products: